Product Details:
Payment & Shipping Terms:
|
Humidity Limits: | 0 – 100% Relative Humidity | Sensing Range: | –300 To 1500 °F (–184 To 816 °C) |
---|---|---|---|
Electrical Connections: | • ½–14 NPT, M20 X 1.5 (CM20), PG-13.5 | Temperature Limits: | –40 To 250 °F (–40 To 121 °C) |
Process Connections: | Transmitter: ¼–18 NPT On 21 /8-in. Centers | ||
High Light: | industrial pressure transducers,pressure indicating transmitter |
Quick Detail:
Description:
Enabled by superior sensor technology and engineered for optimal flow performance, the 3095FB delivers unprecedented reference accuracy with up to 100:1 rangeability. Superior performance results in increased measurement accuracy.
Through aggressive testing, the 3095FB has proven its ability to maintain unprecedented performance under the most demanding conditions. Superior transmitter stability decreases calibration frequency for reduced maintenance and operation costs.
The advanced MultiVariable device measures three process variables simultaneously with optional calculated mass flow and advanced data logging capabilities. One device installation means reduced process penetrations, reduced inventory, and reduced installations costs.
Designed for easy integration with Supervisory Control and Data Acquisition units (SCADA), Distributed Control Systems (DCS), Flow Computers or Programmable Logic Controllers (PLC) and capable of multi-dropping up to 32 transmitters on one RS-485 bus. Easy integration reduces engineering and installation costs.
The flexible coplanar platform allows integration with the complete offering of Rosemount primary elements for any flow application. The solution arrives factory calibrated, pressure-tested, and ready to install right out of the box. Only Rosemount has a scalable coplanar transmitter design to reduce engineering and inventory costs
Applications:
• Gas, Liquid, or Steam
• DP, P, and T with MODBUS output
Specifications:
Bus Terminations | Standard RS-485 bus terminations required per EIA-485. |
Failure Mode Alarm | If self-diagnostics detect a gross transmitter failure, non-latched |
Humidity Limits | 3095FB |
Communications | PC-Based User Interface Software |
User Interface Software and Hardware Requirements: | 3095FB |
Temperature Limits | 3095FB |
Damping | Response to step input change can be user-selectable from 0.1 |
Stability | Range 2-3: 3095FB Ultra for Flow (Option U3)(1) |
Sensing Range | 3095FB |
Ambient Temperature Effects per 50 °F (28 °C) | 3095FB |
Electrical Connections | • ½–14 NPT, M20 x 1.5 (CM20), PG-13.5 |
Process Connections | • Transmitter: ¼–18 NPT on 21 |
Competitive Advantage:
1. Ten years stability under actual process condition
2. Further enhance installation practices with the most reliable platform supported by a 12-year warranty.