|
Product Details:
Payment & Shipping Terms:
|
Output Signal: | Two Wire 4-20mA DC | Ambient Temperature Limits: | -40 To 85℃ |
---|---|---|---|
Response Time: | 1 To 60 Seconds | Supply Voltage: | 7 To 35 V DC |
Mounting: | DIN Form B Head Mounting | Weight: | 50 G (0.11 Lb) |
Accuracy: | ±0.1% Of Span Or ±0.2deg C(0.36deg F) | Signal: | Input Signal Single Input |
High Light: | 4-20ma temperature transmitter,Rosemount Temperature transmitter |
YTA70 Temperature Transmitter for Head Mount / DIN Rail Mount
Quick Detail:
The YTA70 delivers all the benefits found in the YTA50 while adding HART® digital protocol communication. The HART® protocol allows you to conveniently configue the transmitter using the latest FDT/DTM technology. The YTA70 is the choice for all your control applications.
YTA70 features include:
§ 4 to 20 mA DC Analog Output
§ HART® 5 Digital Protocol Output (-E version)
§ Selectable HART® 5 / 7 Digital Protocol Output (-J version)
§ 17 Input Types
§ Head Mount or DIN Rail Mount
Description:
YTA70 Overview
Variety of sensor inputs
The type of sensor input is user-selectable: RTD, Thermocouple (T/C), DC Voltage, or Resistance.
Mounting:
Head Mounting
YTA70 mounted in a #2 connection head.
YTA70 is DIN Form B compliant and can be mounted in a #2 or #9 connection head. It can use an adapter plate to attach to a #5 connection head.
DIN Rail Mounting
YTA70 Single Input
Applications:
Pulp & Paper: Instruments and Solution for Pulp & Paper Industry
Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.
Industry: Pulp and Paper
Specifications:
Accuracy (typical) |
YTA50: ±0.1% of span or ±0.2deg C(0.36deg F) |
Cold junction Compensation accuracy |
(For T/C only) |
Power supply effect |
±0.005% of FS per volt |
Ambient temperature effect |
YTA50: (±0.1% or ±0.1deg C) / 10 deg C |
Input signal |
Single input |
Output |
Two wire 4 to 20 mA DC |
Supply voltage |
7 to 35 V DC |
Ambient temperature |
Option code may affect limits |
Mounting |
DIN form B head mounting |
Weight |
50g (0.11lb) |
Certificates |
CENELEC or FM |
Competitive Advantage:
Temperature Transmitters YTA50/YTA70
Outstanding performance
Microprocessor-based sensing technology ensures high accuracy and stability.
Variety of sensor inputs
The type of sensor input is user-selectable: thermocouples, RTDs, ohms, or DC milivolt.
Digital communication
The YTA70 supports HART communication protocol.
Contact Person: Ms. Shouyan Huo
Tel: +86-18600678435
Fax: 86-10-82561707